Exhaust gas leaves the cylinders of a biogas engine at a temperature of the order of 450–550 °C and should reach the stack after being cooled to a few dozen degrees above the dew point. The exhaust path consists of manifolds, expansion joints, a catalyst (if present), a heat exchanger, a silencer and a stack. Its design affects power, durability and safety, because it operates at the limit of corrosion, noise and the risk of ignition of unburnt mixture. Below we discuss the main elements and constraints. The values are indicative.

Elements of the exhaust path

Exhaust manifolds collect the exhaust gas from the cylinders to the turbocharger. They work at the highest temperatures and are often water-cooled or covered with insulation. Expansion joints absorb thermal expansion and vibration. Damaged expansion joints are a common source of leaks. The silencer limits exhaust noise, usually by means of resonance chambers and sound-absorbing fill, and in larger units it is extended to several sections. The exhaust gas heat exchanger transfers heat to the heating circuit; its details are a separate topic. The stack discharges the exhaust gas at a height that ensures dispersion and meets the requirements of the permit.

Dew point and condensate

Exhaust gas contains water vapour, as well as trace amounts of SO2 and SO3 from the sulphur in the fuel and oil, and nitrogen oxides. After cooling below the dew point temperature of sulphuric acid, of the order of 120–150 °C (depending on the sulphur content), acidic condensate forms on the walls. The dew point of water, in turn, is about 50–60 °C. Condensate has a low pH, usually in the range of 2–4, and destroys carbon steel and seals. For this reason stainless steel of suitable resistance is used in elements where the exhaust gas can cool, and the exhaust gas temperature at the exchanger outlet is kept above the value set by the manufacturer, unless the exchanger is designed as a condensing one.

Slopes and drains

The path should be routed so that condensate runs down to the drain points. The lowest places are fitted with siphons or drains, and their outlet should lead to a neutralisation tank, not to the storm drain. A frozen drain in winter can block the path and cause condensate to accumulate. In a cold climate they are therefore insulated and fitted with trace heating.

Back pressure

Back pressure is the overpressure that the engine has to overcome when discharging the exhaust gas. It is made up of the resistance of the silencer, exchanger, catalyst, ducts and stack. The manufacturer gives a maximum value, usually of the order of several dozen millibars, and in some models up to about 50–60 mbar. Back pressure that is too high causes:

  • a decrease in the amount of fresh charge, and therefore a drop in power,
  • a rise in exhaust gas temperature and in the thermal load on valves and the turbocharger,
  • poorer scavenging of the cylinders and increased NOx.

A clogging catalyst, deposits in the exchanger or an incorrectly selected silencer show up as back pressure rising over time. Monitoring this parameter and its trend is a simple method of early diagnostics.

Stack and dispersion

The height of the stack follows from the emission permit and from the conditions of the location, including surrounding buildings. A taller stack improves the dispersion of pollutants and aids draught, but increases construction costs and requires safeguards. The stack outlet should be protected against precipitation (rain can run down into the silencer) and fitted with measurement ports compliant with the requirements of the standards, so that emission measurements are possible.

Explosions in the exhaust

In the event of a failed ignition or when the engine stops while gas is being supplied, unburnt mixture enters the exhaust path. Ignition from hot surfaces or from the next cycle can result in an explosion that damages expansion joints, silencers and flaps. Several layers of protection are therefore used:

  1. Purging of the engine and the exhaust path before starting, in line with the controller procedure.
  2. Rapid closing of the gas valves on stopping and on an ignition fault.
  3. Monitoring of cylinder ignition and exhaust gas temperatures.
  4. Pressure relief elements (diaphragms or flaps), if the manufacturer provides for them.

To this is added regular inspection of expansion joints and welds, and after every explosion event a check of the whole path.

Practical tips for operations

It is worth recording the back pressure, the exhaust gas temperature upstream and downstream of the exchanger and the quantity of condensate discharged. A change in any of these parameters at constant load is a signal for inspection. Inspections should include a visual assessment of corrosion, tightness and the condition of the insulation, and at every maintenance shutdown an examination of the inside of the silencer.

Sources

  1. FNR — Leitfaden Biogas (Poradnik biogazowy, 7. wydanie, 2016)
  2. KTBL — Kuratorium für Technik und Bauwesen in der Landwirtschaft