Operation and failuresExplainer

Measuring the quantity of biogas: flow meters, pressure and temperature compensation and typical errors

A biogas meter shows a number, but is it the real production? We discuss how flow meters work, compensation and installation errors.

Published 5 min readFeedstockData Editorial Team

Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

Z góry: dwa zbiorniki fermentacyjne z zielonymi dachami i zabudowania biogazowni pośród pól.
Photo Martina Nolte / Wikimedia Commons, licence CC BY-SA 3.0 de, source file; changes: cropping

Measuring the quantity of biogas is harder than measuring natural gas, because biogas is wet, contaminated and of variable composition, and the pressure in the installation is close to atmospheric pressure. The result matters, however: from it we calculate production, CHP unit efficiency, the mass balance and often settlements. Below we describe the principles on which popular flow meters operate and the situations in which the reading departs from reality. Gas composition is a separate issue and is left out here: the scope of this article is solely the measurement of quantity.

Measurement principles

Four main techniques are found at biogas plants.

  • Thermal flow meters measure the cooling of a heated element by the flowing gas. They give a reading close to the mass flow and are relatively simple, but are sensitive to changes in gas composition (CH₄ and CO₂ have different thermal conductivity) and to moisture on the sensor.
  • Ultrasonic flow meters use the difference in the transit time of a wave in the direction of flow and against it. They have no moving parts and work well in clean gas, but condensate and contamination can disturb the signal.
  • Vortex flow meters count the vortices that form behind an obstacle in the stream; they need a higher gas velocity, so at low flows they lose accuracy.
  • Differential pressure measurement (orifice plate, Venturi tube, averaging probe) is based on the dependence of the pressure drop on velocity; it is well documented, but requires stable conditions and regular checking of the pressure tapping points.

The choice depends on the flow range, the gas cleanliness and the space available in the pipeline, and manufacturers give requirements for specific models.

Normal conditions and compensation

The volume of a gas depends on pressure and temperature, so reference conditions are used for comparisons. Normal conditions are the most common: 273.15 K (0 °C) and 101.325 kPa. A volumetric flow meter at operating conditions, e.g. at 38 °C and a pressure slightly above atmospheric, gives a different number from the flow converted to normal conditions. At 38 °C the temperature change alone causes a difference of the order of a dozen or so percent relative to 0 °C.

It is therefore important that:

  1. the flow meter has temperature and pressure sensors or is compensated in the control system,
  2. it is clear in the documentation and in the log whether a given value refers to operating or normal conditions,
  3. the humidity of the gas is taken into account, or the gas is dried before measurement, as recommended by the manufacturer.

The difference between "m³" and "normal m³" is often a source of misunderstandings between the operator, the service company and energy accounting.

Installation location and straight runs

Many errors come from the installation, not from the instrument itself. Manufacturers usually require straight pipe runs upstream and downstream of the flow meter, that is, a dozen or so pipe diameters upstream and a few downstream, so that the velocity profile is stabilised. Elbows, valves and tees right before the sensor disturb the flow. Typical problems:

  • installation close to a blower or control valve, where pulsations and vortices occur,
  • no drainage upstream of the instrument, so condensate floods the sensor,
  • a sensor mounted in the lower part of the pipe, where water collects,
  • vibrations transmitted from the pipeline, which disturb the readings of vortex and ultrasonic flow meters,
  • deposits or contamination on the measuring element.

In unfavourable conditions the measurement error can be several to a dozen or so percent, and the drift trend can be slow and hard to notice.

Why the mass balance can contradict the meter

The operator often compares the amount of substrate, its gas potential and the recorded production. If the difference is 10–15%, there are three possible sources: uncertainty in the feed data (dry matter, organic matter), errors of the flow meter itself and gas losses (leaks, opening of safety devices). Without an independent check it is not known which of them dominates. Verification methods:

  • comparison with the electricity and heat generated by the CHP unit at a known efficiency,
  • measurement with a portable flow meter or checking with two instruments in series,
  • regular calibration checks as recommended by the manufacturer,
  • comparison of trends, not single values: a constant ratio of readings to CHP unit output is useful.

In operating practice it is good to establish a reference point after commissioning or after replacing the flow meter: record the ratio of readings to CHP unit output at a known load. A later deviation of this ratio by a few percent is a signal to check, before anything is changed in the process. It is also worth keeping a record of cleaning and condensate checks at the instrument, because contamination of the sensor is the most common cause of slow drift in readings. The numbers in this text are general and serve to understand orders of magnitude.

Acceptance after installation and the monitoring period

The best moment to detect installation errors is the first weeks after installation. It is worth checking that the flow direction matches the arrow on the housing, that the diameter and units are set correctly in the controller, and that the temperature and pressure sensors are installed close to the measuring point. Good practice is to record the readings together with the CHP unit output at several fixed load points and to repeat the check after a few weeks, when the plant has gone through various operating states. A discrepancy at this stage points to an installation error, not to ageing of the instrument.

Key takeaways

A biogas flow meter is an instrument that requires the right location, drainage, compensation and periodic verification. Before starting to "correct the process" because of a drop in production, it is worth confirming the measurement by another method. The error values in the text are general; the accuracy of a specific type of instrument is given by the manufacturer.

Sources

  1. FNR - Leitfaden Biogas / Fachagentur Nachwachsende Rohstoffe
  2. KTBL - Kuratorium für Technik und Bauwesen in der Landwirtschaft