Digester heating has one task: to maintain a constant process temperature, usually in the mesophilic range of about 37–42 °C, despite changing weather, cold feed and continuous losses through the walls. When it fails, the drop in biogas production appears with a delay, and the cause is often wrongly sought in the biology. We discuss typical designs, degradation mechanisms and diagnostics. The choice between the mesophilic and thermophilic regime and the heat balance of the CHP unit are described in separate articles (including the one on waste heat from CHP); we do not repeat them here.

Two basic heating systems

Internal heating consists of placing pipes with hot water in the tank wall or immersed heat exchangers in the liquid. The advantage is simplicity and no additional pumping of substrate. The drawback is difficult access: repairing or cleaning pipes in the wall is practically impossible without emptying the tank, and immersed heat exchangers become coated with deposits.

External heating uses a heat exchanger through which a pump moves part of the digester contents. The heat exchanger can be cleaned and serviced without entering the tank, but the system depends on the pump and is prone to clogging with fibres. Combined solutions are also found, e.g. heating of the substrate feeder or preheating of the feed.

Deposits and struvite

Heat exchangers work in a difficult environment. A surface at an elevated temperature favours the deposition of mineral compounds. At a high concentration of ammonium nitrogen, phosphorus and magnesium, struvite (magnesium ammonium phosphate) forms and is deposited as a hard layer on pipes and in pumps. In addition, biofilm and organic deposits build up.

The consequence is an increase in thermal resistance. To deliver the same output, a higher heating water temperature is needed, and in an extreme case the heat exchanger stops delivering the required output. The first signals are:

  • a longer run time of the heating circuit pump,
  • a higher flow temperature at an unchanged digester temperature,
  • a smaller temperature difference between flow and return,
  • difficulty maintaining the temperature in winter, although there is no problem in summer.

Failures unrelated to deposits

Not every heating problem is a deposit. The following are common:

  1. Air in the circuit. An airlocked circuit has a lower flow and collects heat only locally; it shows up as noisy pump operation and fluctuating temperature readings.
  2. Circulation pumps. A worn bearing or impeller lowers performance; the drop in flow can be small, so it is easy to overlook.
  3. Three-way and control valves. A blocked actuator sets the valve in the wrong position; the heat goes to the emergency cooler or bypasses the heat exchanger.
  4. Temperature sensors. Drift of the sensor controlling the heating can lead to systematic overheating or underheating, because the controller "sees" a false value.
  5. Damaged insulation of the external heat exchanger or pipelines, which increases losses outside the tank.

Dependence on the heat source

At an agricultural biogas plant the heat comes mainly from the CHP unit. An engine shutdown means no heat and the need to use a backup or emergency boiler. During a longer outage the digester temperature falls by a few degrees per day (depending on the size and insulation of the tank), and swings exceeding about 1–2 °C per day can inhibit methanogens. It is therefore worth planning the heating regime for the case of a CHP unit failure, including a backup heat source and a manual control procedure.

How to detect degradation

The simplest method is a heat balance: comparing the amount of heat delivered to the digester (heating output from the flow and the temperature difference) with the outdoor temperature and the digester temperature. If the heat demand under similar conditions rises from month to month, the heating circuit is losing efficiency. Also helpful are:

  • the trend of flow and return temperature,
  • measurement of the wall surface temperature at several points,
  • checking the cleanliness of the heat exchanger during a shutdown,
  • comparing the readings of the control sensors with a check sensor.

Mechanical or chemical cleaning of external heat exchangers is carried out in accordance with the manufacturer's recommendations. Preventing struvite requires knowledge of the substrate composition, but the doses and methods depend on the specific installation and there is no universal rule here.

Good practice is also to separate, in the data, the heat used to maintain the temperature from the heat needed to warm the feed. Large feeds of cold slurry or silage from a clamp increase the heat demand in a way that is easily mistaken for heat exchanger degradation. It also helps to record the feed temperature and information on when the feeds were larger than usual. This makes it possible to assess whether the rise in demand results from the process, the weather or the equipment, and to plan cleaning or repair at the right moment, and not only in winter.

Key takeaways

Digester heating is a system dependent on the heat exchanger, pump, valves, sensors and heat source. Deposits are a frequent cause of degradation, but not the only one. A constant record of the heat balance makes it possible to detect a problem long before winter, when the heat demand is greatest.

Sources

  1. FNR - Leitfaden Biogas / Fachagentur Nachwachsende Rohstoffe
  2. DBFZ - Deutsches Biomasseforschungszentrum