Periodic emission measurements from a biogas engine: when, who and which methods
A guide to periodic emission measurements from a CHP engine: the basis of the obligation, choosing a laboratory, preparing the unit, methods and conversion to 5% O2.
Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

A biogas engine is a source of emissions to air, so its owner carries out exhaust gas measurements. The scope, frequency and limit values follow from the permit, the notification or other conditions of use of the environment, and the measurement methods from reference standards, and they are carried out by a laboratory with suitable accreditation. This guide sets out the practice and does not give limit values from specific legal acts. The legal position is as at the date of publication: before every measurement you need to check what requirements apply to the given installation and, in case of doubt, seek the opinion of an environmental protection specialist.
Where the obligation to measure comes from
A combustion installation, including a CHP unit on biogas, is subject to requirements arising from national air protection regulations that implement, among others, Directive (EU) 2015/2193 on medium combustion plants. For the owner, the specific obligations are set by the decision (permit) or the notification document, which states the parameters (usually NOx, CO, possibly SO2, dust, formaldehyde), the frequency of measurements and the way results are submitted. The frequency varies, for example once a year or once every few years, depending on the capacity of the installation and the provisions of the decision. One should follow the schedule from the document, not what the neighbours do.
Choosing a laboratory
The measurements are carried out by a laboratory that holds accreditation for emission measurements from stationary sources and for methods compliant with the requirements of the permit. When placing the order it is worth checking:
- Whether the scope of accreditation covers the parameters and methods named in the decision.
- Whether the laboratory has experience in measurements on gas engines (dry exhaust gas, low concentrations, high oxygen share).
- Whether the offer covers everything: sampling, analysis, report and the uncertainty of the result.
- What the lead time is and whether the laboratory has equipment for winter work.
Preparing the unit
The measurement should reflect typical operating conditions, not particularly favourable ones. Typical requirements are:
- operation at a load close to nominal (often at least about 80–100% of power) and stable, established at least several dozen minutes after start-up,
- a properly working control system, with no service work immediately before the measurement that could change the settings in an atypical way,
- stable gas composition during the test, with CH4 and load recorded,
- available measurement ports and safe access to the stack (platform, walkway, 230 V supply).
It is better to carry out the measurement after a service, but with the settings documented, than right before an inspection, when wear is greatest, because the result will then show how much margin the installation has.
Reference methods
NOx (the sum of NO and NO2, expressed as NO2) is determined according to the standard EN 14792, most often by the chemiluminescence method. CO is determined according to the standard EN 15058, usually by non-dispersive infrared absorption. SO2, dust, formaldehyde or additional parameters are measured by the methods indicated in the permit and the standards cited by the laboratory. For engines with a catalyst it is worth ordering measurement upstream and downstream of it, because this gives information on its condition.
Conversion to 5% O2 in dry exhaust gas
Limit values usually refer to dry exhaust gas and a standardised oxygen content, for engines most often 5% O2. The conversion is carried out according to the formula:
C(5%) = C(measured) × (21 − 5) / (21 − O2 measured)
An illustrative example: a measured NOx of 400 mg/m³ at 8% O2 in dry exhaust gas gives 400 × 16 / 13 ≈ 492 mg/m³ at 5% O2. The difference shows why comparing a result without conversion leads to errors. The result is expressed under normal conditions (temperature 273 K, pressure 101.3 kPa), unless the permit indicates otherwise.
Report and archiving
The measurement report should contain the installation data, the operating conditions (load, gas composition), the methods, the results, the uncertainty and a comparison with the limit values. The original is kept in the operating documentation, and the results are submitted wherever the decision requires. The retention period follows from the regulations and the decision, and in practice it is recommended to keep reports for at least several years in order to show the trend.
What to do if a limit is exceeded
- Verify the data: operating conditions, calibration, conversions.
- Investigate the cause: the lambda setting, the condition of spark plugs, valves, the catalyst, gas and oil quality.
- Contact the service provider and carry out a repair or adjustment.
- Report the fact to the authority, if the decision requires it, and repeat the measurement after repair.
- Record the event in the documentation.
Systematic measurement of CO and NOx with your own flue gas analyser during inspections makes it possible to catch a trend before a control measurement takes place. The types of permits and notifications from which measurement obligations arise are discussed in the article Environmental permits for a biogas plant: emissions, integrated permit and notifications.