Electricity balance of a biogas plant: gross production, own consumption and net sales
How to break down a biogas plant's energy into gross production, own consumption, losses and net sales, how to arrange the meters and where differences come from. With a table and KPIs.
Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

A biogas plant produces electricity, but it also consumes it: for mixing, pumping, feeding substrates, compressing gas, cooling and lighting. The electricity balance separates these streams into gross production, own consumption, losses and net sales, which makes it possible to assess the efficiency of the installation and to reconcile the data with settlements. The guide shows how to build such a balance, how to place the meters and where discrepancies come from. We give the figures as typical ranges, and omit specific tariffs and prices.
Basic concepts
- Gross production is the energy generated by the generator, measured at its terminals.
- Own consumption is the energy used by the biogas plant equipment (digesters, pumps, compressors, chillers, offices, lighting), and also by the unit itself (coolant pumps, fans, controls).
- Losses in the transformer and cables, usually 1–3% of production.
- Net sales (export to the grid) is gross production minus own consumption and losses.
The relationship: E_net = E_gross − E_own − E_losses.
What own consumption consists of
At an agricultural biogas plant the largest items are the agitators in the digesters (often 30–50% of own consumption), substrate and digestate pumps, solid substrate feeders, fans, the gas chiller and blowers, and auxiliary equipment (desulphurisation, compressors). In total own consumption is, indicatively, from a few to a dozen or so per cent of gross production, depending on the design, the type of substrate and the way of mixing. Biogas plants with a lot of continuous mixing, separation and additional equipment can exceed this range, while modern, well-designed ones fall in its lower part.
Metering arrangement
The basic arrangement includes:
- A production meter at the generator output (gross energy), often showing active and reactive energy.
- A settlement meter at the connection point, bidirectional: energy exported to the grid and imported from the grid.
- Sub-meters of consumption on selected loads (agitators, pumps, compressors, cooling), which make it possible to identify the largest consumers.
Requirements for accuracy class, sealing and verification follow from the agreement with the grid operator and the regulations, so they should be checked as at the current legal position. Settlement with the operator is based on the settlement meter, not on the production meter, which is why the two have to be compared with each other.
Why meter differences can be large
Typical causes of discrepancies between gross production and net sales:
- own consumption higher than assumed, for example after a change of substrate or the addition of agitators,
- energy drawn from the grid while the unit is stopped (supply of agitators and pumps, heating),
- losses in the transformer, especially at low load, because no-load losses occur around the clock,
- differences in calibration and meter class,
- reactive energy and compensation, if the meter measures only active energy,
- the way the balance is settled (hourly or monthly), which changes the amount of energy treated as exported and imported.
Example (illustrative)
A biogas plant with a 500 kW el. unit, 8,000 h/year.
| Item | Annual energy | Share |
|---|---|---|
| Gross production | 4,000,000 kWh | 100% |
| Own consumption of the biogas plant | 400,000 kWh | 10% |
| Transformation and cable losses | 60,000 kWh | 1.5% |
| Net sales | 3,540,000 kWh | 88.5% |
| Import from the grid during stoppages | 40,000 kWh | – |
In this example the energy exported to the grid is 3,540,000 kWh, and the energy imported is 40,000 kWh. If the meter showed 3,300,000 kWh, the difference of 240,000 kWh (6%) would be a signal for inspection: a meter error, unaccounted consumption or unit outages.
KPIs
Useful indicators:
- Own consumption as % of gross production, calculated monthly.
- Own kWh per tonne of substrate, usually in the range of several dozen kWh per tonne for agricultural biogas plants (depending on the substrate).
- Own kWh per Nm³ of biogas.
- Net efficiency: net sales relative to the energy contained in the gas.
A fall or rise of the indicator over time is a signal: a rise in consumption per tonne can mean worn agitator bearings, mixing that is too intensive or a denser digester content.
How to keep the balance
- Collect meter readings at the same frequency (ideally hourly from the control system, with a monthly check from the invoice).
- Draw up the balance every month and compare it with previous periods.
- Analyse larger deviations and check the sub-meters.
- Record changes in the installation that may affect the result, and periodically verify the meter verification status.
A well-kept balance makes it possible to find the sources of losses quickly and to document the real efficiency of the installation. The efficiency of the unit itself, without the own consumption of the whole installation, is described in the article The CHP engine at a biogas plant: electrical and thermal efficiency and part-load operation.