Process biology and start-upExplainer

Hydrogen and biogas composition as an early indicator of digester overload

A rise in hydrogen and a change in the CH₄ to CO₂ ratio usually precede changes in pH and FOS/TAC. The mechanism, sensor limitations and reading the trend after a feed.

Published 5 min readFeedstockData Editorial Team

Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

Rzędy szklanych reaktorów BMP w termostatowanej łaźni wodnej, wężyki prowadzą do wielokanałowego miernika przepływu gazu.
Illustration: FeedstockData (AI, Google Gemini)

Hydrogen in biogas is a gas formed at the stage of acidogenesis and acetogenesis, whose concentration reflects the balance between the production of acids and the community's ability to break them down further. It is usually present in trace amounts, in the order of several tens of ppm, but it reacts to overload faster than parameters measured in the liquid, which is why it is sometimes used as an early-warning indicator.

Why H₂ plays such an important role

In the stage of acidogenesis and acetogenesis bacteria oxidise propionate and butyrate to acetate, hydrogen and CO₂. These reactions are thermodynamically possible only at a very low partial pressure of hydrogen, usually below approx. 10–100 Pa (a narrower window for propionate than for butyrate). Hydrogen is consumed by hydrogenotrophic methanogens, which form CO₂ and methane from it. If the community cannot keep up with its consumption, the partial pressure rises, and the breakdown of propionate slows or stops.

The effect is a chain:

  1. excess load increases the rate of production of acids and hydrogen,
  2. hydrogen rises, which inhibits the oxidation of propionate and butyrate,
  3. the accumulation of propionate lowers the pH and further inhibits methanogens,
  4. methane falls, CO₂ rises, and finally pH falls.

Hydrogen is at the beginning of this chain, and pH at the end, after the carbonate-ammonium buffer has been used up. Hence the time advantage of the gas indicator.

What overload looks like in biogas composition

With a slight overload the following can be observed: a rise in H₂ (from several tens to several hundred ppm, depending on the plant and the measurement method), a slight drop in CH₄ concentration (e.g. by 1–3 percentage points) and a corresponding rise in CO₂. Volumetric production may initially rise (more CO₂ and hydrogen from rapid acidogenesis), which can be misleading. Only afterwards does it fall.

Indicative relationships:

Signal in the gas Possible meaning
a rise in H₂ after a feed, a return to baseline within hours a normal response to load
a rise in H₂ lasting a day or longer overload, slowdown of syntrophy
a drop in CH₄ with a rise in CO₂ a shortage of methanogen activity
a drop in CH₄ at constant H₂ possibly another problem, e.g. a deficiency of trace elements or inhibition

The ranges depend on the plant, the composition of the substrates and the type of sensor. Your own baseline is more important here than numbers from the literature.

Interpreting the daily trend after a feed

The response of hydrogen to a feed has dynamics. Within several hours after the feedstock is fed the concentration rises, reaches a maximum, and then returns to the starting level. The diagnostic information is:

  1. the height of the peak relative to previous days at the same feed rate,
  2. the time to return to baseline, which lengthens with overload,
  3. the baseline before the feed, which rises in a lasting disturbance.

Continuous recording makes it possible to see these indicators, whereas a one-off measurement can be misleading: the value 3 hours after a feed will be different from that in the morning. For constant comparison conditions, the measurement is taken at a fixed time relative to feeding. In addition there is the comparison with the FOS/TAC measurement and the VFA profile, which confirm or exclude overload.

Limitations of sensors and analysers

  • Range and sensitivity. Electrochemical hydrogen sensors have a limited range and may not detect values at the low end; chromatographic analysers are accurate but rarely available at agricultural biogas plants.
  • Cross-sensitivity. Some sensors also react to other reducing gases, e.g. CO and H₂S, so the hydrogen reading may be overstated. The sensor manufacturer usually gives a list of interferents.
  • Drift and calibration. Sensors lose sensitivity over time and in the presence of contaminants, so they must be calibrated regularly with a reference gas.
  • Sampling point. A measurement at the digester outlet, before drying, differs from a measurement in dried biogas; moisture and condensate affect the result. Much also depends on whether gas from different tanks is mixed.
  • Dilution. In systems with several digesters and a common manifold, the signal from one overloaded tank is diluted.
  • Safety. Gas measurements in explosion hazard zones are carried out with equipment of the appropriate category.

For these reasons H₂ is a supplement, not a replacement for the classical indicators. It is also worth using the CH₄ and CO₂ measurement, which is the standard and gives a continuous picture.

How to use this in operation

  1. Set a baseline in stable conditions: the typical level of H₂, CH₄ and CO₂ and the shape of the response to a feed, on several different days.
  2. Define relative alarm thresholds, e.g. a rise in baseline H₂ by a set multiple or a drop in CH₄ of several percentage points relative to the average of recent days.
  3. React early: at the first signals reduce the feed rate or separate out the most acidifying feedstock component, before the pH changes. Details of the actions are described in the guide on acidification.
  4. Confirm with laboratory measurements (FOS/TAC, VFA) before making deeper changes.
  5. Document: recording trends makes it possible over time to determine your own reliable threshold.

Conclusions

Biogas composition, and in particular hydrogen, gives insight into the state of the process in near real time and often precedes changes in pH. It has its full value, however, only with continuous measurement, your own baseline and confirmation in chemical analyses. Absolute values from the literature can be treated only as an orientation point.

Sources

  1. Weiland P. (2010), Biogas production: current state and perspectives
  2. Chen Y., Cheng J.J., Creamer K.S. (2008), Inhibition of anaerobic digestion process: A review