Specific biogas yield: how normalisation to m3N and measurement uncertainty change the assessment of the biology

Specific yield only makes sense once the gas is brought to normal conditions. We show the correction calculation, how uncertainties combine and what it means for the biology.

Published 5 min readFeedstockData Editorial Team

Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

Detal laboratorium BMP: szklane butelki z kapslami i gumowymi korkami w statywie inkubatora oraz szczelna strzykawka do gazu na blacie.
Illustration: FeedstockData (AI, Google Gemini)

Specific yield of biogas and methane is the ratio of gas volume to the amount of volatile solids (VS) processed, expressed in m3N per tonne of VS. For this figure to say anything about the biology of the digester, the volume must be brought to the same reference conditions as literature values and BMP test results. A gas meter, however, shows cubic metres at operating conditions: at the gas temperature, at its pressure and including water vapour. Below we explain how to convert it and how to judge the reliability of the result. The design and selection of flow meters is covered in a separate article on biogas flow measurement; here we deal with the calculation itself and its consequences for assessing the biology.

Why the raw reading is not enough

Gas volume depends on temperature and pressure, and biogas from the digester is warm and saturated with water vapour. At 35 °C water vapour takes up about 5.6% of the volume, so wet gas contains less methane in the same volume. In addition, the pressure in the installation is often a few millibars above atmospheric. If in one month the gas condenses earlier in a cold pipe than in a warm period, the volumetric reading will change without any change in the biology.

In Poland and in most of the literature, normal conditions are taken as 0 °C and 101.325 kPa, with the gas treated as dry. Always state in the report which basis you use (dry or wet, 0 °C or 15 °C), because the difference between 0 and 15 °C is about 5.5% of volume.

The correction formula

The normalised volume is:

V_N = V × (p − p_w) / 101.325 × 273.15 / (273.15 + T)

where V is the measured volume (m3), p is the absolute gas pressure (kPa), p_w is the partial pressure of water vapour at the gas temperature (kPa), and T is the gas temperature in °C. For saturated gas, p_w is read from tables: approx. 3.2 kPa at 25 °C, approx. 5.6 kPa at 35 °C, approx. 7.4 kPa at 40 °C.

Worked example

Assumptions (illustrative, not a measurement of a specific installation):

  1. measured daily volume: 14,000 m3 at operating conditions,
  2. gas temperature at the meter: 35 °C, gas saturated with vapour,
  3. overpressure of 5 mbar at an atmospheric pressure of 101.325 kPa, i.e. p ≈ 101.8 kPa,
  4. methane content 52% in dry gas,
  5. throughput: 20 t of VS per day.

Calculation: (101.8 − 5.6) / 101.325 = 0.949, and 273.15 / 308.15 = 0.886. The correction factor is therefore 0.841, i.e. V_N ≈ 11,780 m3N of dry biogas per day. Methane amounts to 0.52 × 11,780 ≈ 6,130 m3N. Specific yield: approx. 589 m3N of biogas and approx. 306 m3N of CH4 per t of VS.

Without the correction the result would be 700 m3 per tonne, i.e. 19% too high. Someone comparing this with a literature value might conclude that the biology is performing very well, when it is merely average. Likewise in winter, at a lower gas temperature, the raw reading apparently falls.

Uncertainty of specific yield

Specific yield is the quotient of two quantities measured with error: the normalised volume and the VS throughput. When the errors are independent, relative uncertainties are combined geometrically. Example with illustrative assumptions: gas meter with compensation ±3%, volatile solids analysis of substrates ±8%, weighing of the feed ±2%. The resulting uncertainty is the square root of the sum of squares: √(3² + 8² + 2²) ≈ 8.7%. For a yield of 589 m3N/t VS this gives a range of about ±51 m3N, i.e. from 538 to 640.

The conclusion is practical. A change in yield from 589 to 570 (by 3%) falls within measurement noise and does not justify claiming that the biology has deteriorated. Only a lasting fall of the order of ten-odd percent, visible in an average over several weeks and confirmed by another parameter, is a signal worth acting on. The largest share of uncertainty is usually the VS analysis of the substrates, so improving its quality (representative samples, repeats) gives more than replacing the gas meter.

Where to carry out the normalisation

The correction should be calculated using the temperature and pressure values from the measurement point, not from an average for the whole installation. A measurement upstream and downstream of the blower gives different pressure and temperature. If the gas meter has built-in compensation, record whether it returns dry or wet m3N, and do not correct a second time. A combined measurement from several digesters does not separate the causes, so wherever possible measure each digester separately.

Reliability checks

Before you interpret a change in yield as a change in the biology, carry out several independent checks:

  1. Balance against the engine or boiler. The gas consumption of the unit can be calculated from the energy produced: V_N = P_el / (η_el × H_u), with a calorific value of methane of approx. 9.97 kWh/m3N. Agreement with the gas meter within a few percent is a good sign; a discrepancy of 10% or more needs checking.
  2. Zero test and verification. Compare against a reference gas meter or a control verification in line with the manufacturer's schedule.
  3. Density and composition. The CH4/CO2/O2 analyser should have a valid calibration with reference gas; check that it measures on dry gas.
  4. Trend of several parameters. A change in gas alone, without a change in VFA, pH and temperature, is more suspect as a measurement issue than as a biological one. The principles of keeping such records are described in the article on biogas flow measurement.

Typical interpretation errors

  • Comparing months without correcting for gas temperature and moisture.
  • Mixing dry and wet bases in one KPI summary.
  • Using fresh-mass throughput from a scale with a large error in VS content (the VS analysis error often exceeds the gas meter error).
  • Treating a single day as a reliable data point; a rolling average over several days makes more sense.
  • Failing to document changes: replacing a sensor or moving the installation point creates a step in the data that looks like a change in the biology.

Good practice is to keep a measurement log with the dates of replacement, calibration and cleaning, and always to state the normalisation basis. Then a conversation about the biology starts from reliable figures, not from measurement artefacts.