Alkalinity is the capacity of a liquid to take up acids without a large change in pH; in a digester it is formed above all by bicarbonates, and the TAC measurement (total alkalinity, mg CaCO3 per litre) is its practical measure. When the methanogens cannot keep up with acid production, it is the alkalinity that takes the first blow. Understanding where it comes from makes it possible to predict when the buffer is strong and when it is thin. The practical interpretation of the indicators is discussed in the article on FOS/TAC, and the pH relationship in a separate text on pH. Here we concentrate on the chemistry.

The carbonate system

CO2 dissolves in the liquid and forms carbonic acid, which dissociates into bicarbonate:

CO2 + H2O ⇌ H2CO3 ⇌ H+ + HCO3-

For mesophilic temperature pKa1 is about 6.3. The Henderson-Hasselbalch equation gives: pH = pKa1 + log([HCO3-] / [dissolved CO2]).

The concentration of dissolved CO2 follows from Henry's law, i.e. from the partial pressure of CO2 in the gas. Biogas typically contains 40-45% CO2, so at a pressure close to atmospheric, dissolved CO2 is about 10 mmol/l (at 38 °C).

Example

Assumptions: pCO2 ≈ 0.42 atm, Henry's constant approx. 0.025 mol/(l·atm) at 38 °C, pKa1 = 6.3, pH = 7.4.

  • [dissolved CO2] ≈ 0.025 × 0.42 ≈ 10.5 mmol/l,
  • ratio HCO3-/CO2 = 10^(7.4 − 6.3) = 10^1.1 ≈ 12.6,
  • [HCO3-] ≈ 132 mmol/l, i.e. alkalinity approx. 132 meq/l ≈ 6.6 g CaCO3/l.

The result falls within the ranges encountered in practice (a few to over ten g CaCO3/l), but it is an illustrative calculation. It does, however, show the relationship: at the same alkalinity a lower CO2 content in the gas raises the pH, and a higher one lowers it. This is why a change in the composition of the mix can change the pH without adding bases.

Where alkalinity comes from

  1. Breakdown of proteins and urea. Amino acids are deaminated to ammonia, which with CO2 and water forms NH4+ and HCO3-. This is the main source of alkalinity in digesters fed with slurry, slaughterhouse waste or poultry manure.
  2. Slurry and additives. Slurry itself contains bicarbonates, and mineral additives in feed also pass into the feedstock.
  3. Breakdown of salts of organic acids. The breakdown of acetates and other salts releases bicarbonate ions.
  4. Nitrogen-poor substrates. Maize silage, grass, stillage or sugar wastes yield little ammonia; the digester runs on a thin buffer.

The NH4+/NH3 pair (pKa approx. 9.0 at 38 °C) also acts as a buffer, but at pH 7.2-7.8 it is a weaker one; ammonia acts mainly by raising total alkalinity and pH. Too much free ammonia (NH3), in turn, becomes an inhibitor.

What consumes alkalinity

Volatile fatty acids react with bicarbonate: RCOOH + HCO3- → RCOO- + CO2 + H2O. Each mole of acid consumes a mole of alkalinity, and the CO2 formed goes into the gas. As long as the buffer is large, the pH hardly changes, so a fall in pH is a delayed signal; earlier, the FOS changes and alkalinity falls. When the rate of acid production exceeds buffering, the pH begins to fall quickly and the process enters an acidification spiral (more in the text on acidification).

How to raise alkalinity

The options below are general in nature; we give no doses, because they depend on volume, composition and purpose.

Changing the mix. Increasing the share of slurry or protein substrates raises alkalinity gradually and without risk to the chemistry of the liquid, but it acts slowly (days to weeks). It should be taken into account that more nitrogen means more ammonia.

Sodium bicarbonate. It raises TAC quickly and does not change the pH abruptly. Drawbacks: it adds sodium (accumulation in the circuit, an effect on methanogens at high concentrations and on digestate quality), it costs money, and the effect passes with throughput.

Lime (calcium hydroxide or oxide). It strongly raises pH and alkalinity and is cheap. Risks: local pH spikes during dosing, precipitation of CaCO3 (it consumes CO2 and alkalinity, so part of the effect is apparent) and the deposits described in the article on struvite and deposits. Bases are always added slowly, dispersed, with intensive mixing.

What about strong bases (NaOH)? They require the greatest caution: the pH locally exceeds the range in which methanogens can live, and sodium accumulates. They are used only in justified cases and under control.

Precautions

  1. Diagnose the cause. Adding bases without removing the source of acids is treating a symptom.
  2. Change alkalinity in small steps and measure TAC and FOS after each step, allowing for the mixing delay.
  3. Pay attention to the gas: a rise in pH with a simultaneous fall of CO2 in the gas may indicate too strong alkalisation.
  4. Do not correct pH without knowing the ammonia content; at high NH4-N a rise in pH increases the share of toxic NH3.
  5. Keep a record of doses, dates and measurement results, because after a few episodes you build knowledge of the sensitivity of your own installation.

Alkalinity is a resource that can be strengthened or consumed. The most durable way is a mix composition that supplies the buffer by itself, leaving chemical additives for temporary interventions.