Falling biogas production: what not to do and how to read the symptoms when a decision has to be made quickly
Under time pressure it is easy to harm the digester. We match symptoms to a first action and point out reactions that are better avoided.
Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

A fall in biogas production is a symptom, not a diagnosis, and the operator's first reactions often decide whether the episode ends in a few days or in a few weeks. The full order of searching for the cause (measurement, feedstock, biological process, mechanics) is described in the article on the diagnostic tree for the operator. Here we assume that this order is known, and concentrate on what to do and what not to do before the cause is certain. The scheme is general and does not replace analysis of a specific installation.
Why the same mistakes are made under pressure
A fall in gas is a fall in revenue, so there is a natural urge to "make up" the loss quickly. Many typical reactions (increasing the dose, adding a supplement, changing several parameters at once) stem precisely from this pressure. Meanwhile the biomass reacts in days (explained in the article on kinetics and generation times), and the effects of a hasty decision appear with a delay, when it is hard to link them to the cause.
A simple rule helps: before you change anything in the dose or the supplements, carry out three checks that cost nothing and spoil nothing. First, compare the gas meter reading with the balance of engine operation (details in the article on specific yield). Second, check the delivery records and the analyses of the substrate batch. Third, measure pH, FOS/TAC and VFA, because these distinguish a biological disturbance from a change of material. The interpretation of the indicators is described in the text on FOS/TAC, and for elevated acids in the one on acidification.
Table: symptom, cause, first action
| Symptom | Probable cause | First action | What not to do |
|---|---|---|---|
| Fall in gas, no change in VFA and pH | measurement error, less degradable matter in the substrate | check the gas meter and balance against the engine, VS analysis of the batch | increase the dose "to make up" |
| Fall in gas and methane, rise in VFA | overload, inhibitor, nutrient deficiency | reduce or stop the dose of rapidly degradable substrates, measure VFA and FOS/TAC | add many supplements at once |
| Fall in gas and pH, high FOS/TAC | acidification | follow the acid procedure, relieve the load | add bases abruptly |
| Fall in gas, high NH4-N, pH above 7.8-8 | ammonia inhibition | change the mix, dilute, control temperature | raise pH and temperature |
| Fall in gas after a change of substrate | change in batch quality | compare analyses, possibly blend batches | change several components at once |
| Fall in gas with foaming | change of substrates or fats | control foaming, antifoam dose in line with the rules | switch off mixing without analysis |
| Fall in gas and fall in temperature | heating failure or deposit on the exchanger | repair, cleaning | maintain the full dose at low temperature |
| Step fall after a mixing failure | scum, dead zones | restore mixing gradually, control acids | abruptly switching on at full power without inspection |
Stop and escalation rules
It is worth establishing in advance when the operator stops acting alone. Example criteria, which every installation should adapt to its own data: a lasting fall in gas production over several days despite a confirmed measurement, a rising FOS/TAC with a falling pH, a sudden change in gas composition, or a VFA analysis result indicating a build-up of propionate. In such a case the decision to reduce the dose and call a process adviser is not a sign of failure but a cheaper route than a late intervention after acidification. Record every such decision with the time, the reason and the values of the indicators, so that it can be assessed later.
General principles
- One change at a time. When several factors are changed at once, it is not known what worked.
- Time. The biomass reacts in days (explained in the article on kinetics and generation times); do not assess the effects after a few hours.
- Documentation. Record dose changes, failures, analysis results and observations; after a few episodes you build your own database of causes.
- Safety. If a release of gases or an explosion hazard is suspected, health and safety procedures apply, and biological diagnostics are secondary.
What to avoid
- increasing the dose in reaction to a fall in gas, because during a disturbance this deepens the overload,
- using supplements without analysis (they may mask the cause or add problems),
- emptying the digester before simpler diagnoses are exhausted (the decision to replace the contents is costly),
- comparing with other installations without allowing for differences in mix and temperature.
An orderly sequence of actions shortens the time needed to reach the cause, but does not replace the operator's experience. In difficult cases it is worth using independent laboratory analysis and consulting a process adviser.