The documentation of every gas engine contains a sheet of fuel requirements, often called the gas specification or fuel data sheet. It is a set of limit parameters, compliance with which is a condition of the declared power, service life and, quite often, the warranty. The guide below shows how to read such a sheet and how to turn it into measurement practice at a biogas plant. We present only the reading of the parameters and the consequences of exceeding them, not gas treatment methods. The values in the table are typical ranges and do not replace the manufacturer's document.

Physical parameters

Supply pressure. The manufacturer gives the gas pressure range upstream of the gas train (typically from a dozen or so to several dozen mbar, and more for engines with a high-pressure blower) and the maximum permissible change over time, for example in mbar per second. Fluctuations cause instability of the mixture composition and misfires, and pressure that is too low limits power.

Temperature and humidity. Gas from the digester is saturated with water vapour. The specification usually requires a gas temperature a dozen or so degrees lower than that around the gas train and a relative humidity below about 80%, so that condensate does not form in the fittings. Condensate damages valves, dilutes the oil and promotes corrosion.

Calorific value and methane. The data sheet states the minimum CH4 content or the minimum calorific value and the maximum rate of change, because the controller can keep up only with slow variations in composition. For agricultural biogas the typical working range is about 50–65% CH4.

Contaminants

Parameter Typical order of magnitude permitted Consequence of exceeding
Siloxanes (as Si) usually below 5 mg/m³, depending on the model hard SiO2 deposits in the chamber, on valves and spark plugs, rapid wear
Chlorine and fluorine (combined) usually up to approx. 100 mg/m³ expressed for gas with 100% methane acid corrosion, shorter oil life
Ammonia usually several dozen mg/m³ higher NOx, deposits in the system
Hydrogen sulphide in the specification usually in the range from several hundred to approx. 1000–2000 ppm, depending on the oil and engine oil acidification, corrosion, accelerated replacement
Dust and particles below a few mg/m³ abrasion, clogging of filters

When the data sheet states the concentration expressed per methane (for example mg/m³ CH4), and we measure in raw gas, it has to be converted using the methane share. At 55% CH4 the permissible concentration in raw gas is proportionally lower than the value given for pure methane (in this example about 55% of that value). This is a common interpretation error.

Hydrogen sulphide as a limit parameter

H2S appears in the data sheet as the upper permissible concentration at the engine inlet. The manufacturer usually links it to the oil change interval and to the requirement for the oil's total base number (TBN): the higher the H2S concentration, the faster the oil acidifies. Exceeding the limit value does not mean immediate failure, but it shortens inspection intervals, can void the warranty and accelerates corrosion of the exhaust system. In operating practice what matters is the current value, the trend and the momentary peaks, not only the daily average.

How to translate the specification into a measurement plan

  1. List the parameters from the data sheet together with their units and the basis of conversion (normal m³, conversion to CH4).
  2. Group them by frequency. Continuous: pressure upstream of the gas train, temperature, CH4, H2S, often O2 and CO2. Periodic: siloxanes, halogens, ammonia, total dust content. Relative humidity is derived from temperature and pressure, so it can be calculated.
  3. Determine the sampling point in line with the manufacturer's requirement, usually just upstream of the gas train, not in the digester.
  4. Plan calibrations of the continuous analysers and a periodic comparison with laboratory measurement.
  5. Define alarm thresholds at 80–90% of the limit value, to leave time to react before it is exceeded.
  6. Record responsibility and response: who receives the alarm, what the operator does, whom they notify.

How to use the data in service and in discussions with the manufacturer

Well-documented results are an argument in a warranty dispute and the basis for lengthening or shortening oil change intervals. A set of oil analyses, the H2S trend and the results of periodic contaminant measurements make it possible to assess whether the interval in the data sheet is right for a given installation. When the substrate changes or a new component is added, it is good to repeat selected analyses, because the contaminant profile can change within weeks. Where siloxanes and hydrogen sulphide in biogas come from is explained in the article Biogas pre-treatment: H2S, siloxanes and water before upgrading. Condensate in gas fittings is also relevant to biogas drying.

Summary

A gas specification is not a wish list but a boundary condition of engine operation. Read it together with the oil documentation, convert the units with full care and build from it a concrete measurement plan, with alarm thresholds below the limits. This will help avoid the most expensive mistakes, namely slow degradation that cannot be seen in daily readings.

Sources

  1. FNR — Leitfaden Biogas (Poradnik biogazowy, 7. wydanie, 2016)
  2. DVGW — Deutscher Verein des Gas- und Wasserfaches