Tanks and membranesExplainer
Concrete for biogas tanks: exposure classes, watertightness and chemical attack
The concrete of a digester tank works among organic acids and moisture. How to read the exposure classes in EN 206 and why w/c and cover matter.
Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

Concrete in a digester tank has two tasks: to carry loads and to be tight against liquid and gas for ten or several dozen years. The condition for durability is a conscious selection of concrete for the actual exposure, not merely specifying a strength class. The basis is the PN-EN 206 standard, and the design framework for tanks comes from Eurocode 2 Part 3.
Exposure classes in PN-EN 206
The standard describes the environment acting on concrete through exposure classes. For biogas tanks the main ones are:
- XC – carbonation, reinforcement corrosion caused by the penetration of CO₂ (gas zone and walls exposed to changes in humidity),
- XA – chemical attack (XA1–XA3, from weak to strong),
- XF – freeze-thaw cycles, relevant for external walls and roofs,
- XD and XS – chlorides, less relevant in this application.
A single structure usually has several classes at once: different ones for the submerged part, for the gas zone and for the outer surface of the wall. The designer should specify them for each zone separately. The XA class requires an assessment of the chemical composition of the medium, in which the concentrations of organic acids, ammonia and sulphates provide the basis for assigning it.
Where chemical attack comes from
The liquid in a digester contains volatile fatty acids, ammonium nitrogen and sulphur compounds. Organic acids in low concentration act on concrete slowly, dissolving components of the cement paste. Ammonia and ammonium ions can cause calcium leaching. Sulphates react with the aluminate phases of cement and can lead to swelling. In the gas zone the problem is acidic condensate, described later in the section.
Parameters that decide durability
The most important include:
- Water-cement ratio (w/c): the lower it is, the lower the porosity and permeability. For chemical attack classes the standard sets maximum values and a minimum cement content; for higher XA classes a w/c of around 0.45–0.50 or lower is usually targeted, in line with the tables of the standard and the project requirements.
- Type of cement: with sulphate attack, cements with increased sulphate resistance (SR designations) or with additions such as blast furnace slag are used, if the standard and the documentation permit it.
- Compaction and curing: even a good mix loses tightness if the concrete is poorly compacted or dries out in the first days.
- Reinforcement cover: the thickness of concrete over the bars is selected for the exposure class and the expected service life, and maintained on site with spacers.
- Watertightness: for tanks, concrete with reduced water absorption is adopted, often with a requirement for water penetration depth according to a test, set in the specification.
Eurocode 2 Part 3 as a design framework
PN-EN 1992-3 covers concrete structures for storing liquids and gases, so it contains requirements for cracks, tightness classes and minimum reinforcement limiting the effects of shrinkage. The details and national parameters depend on the national annex. The document does not replace the design: it indicates how to link tightness with crack width and pressure gradient.
Quality control in practice
The client may require:
- a mix recipe stating the strength class, exposure classes, w/c and cement type,
- tests of control samples (strength, sometimes watertightness),
- concreting records: temperature, transport time, curing method,
- acceptance of the reinforcement before concreting (cover, spacers).
It is worth collecting the documentation as work proceeds; after concreting it is hard to reconstruct.
Curing and concreting conditions
A tank of large diameter is concreted in stages, so it is worth planning in advance the sequence, the locations of construction joints and the way they are sealed. At low temperatures concrete gains strength more slowly and is more susceptible to frost damage in the first days, and in heat it risks too rapid drying of the surface. Curing therefore consists of keeping the concrete moist and sheltering it from wind and sun, and in winter of thermal protection. Recording these conditions in the site diary is one piece of evidence that the concrete was made in line with the design assumptions.
Typical mistakes
The most common are a single class for the whole tank without distinguishing zones, underestimating attack in the roof slab, poor curing in winter, and technological breaks in concreting without proper joining (construction joints require sealing strips). Each of them may later appear as a leak or a crack.
What to look out for
A practical tool for the client is a table of tank zones with assigned exposure classes, maximum w/c, minimum cement content and cover. Attached to the specification, it organises the discussion with the concrete plant and the contractor and makes the later acceptance easier. The absence of such a table often means that the concrete was selected in general terms, not for the working conditions of the tank.
Summary
Good concrete for a biogas tank is the result of consistency between the exposure class, the recipe, the workmanship and the curing. The PN-EN 206 standard provides the language for describing the environment, and Eurocode 2 Part 3 the design framework. The following texts in the section cover cracks, corrosion in the gas zone and interior protection.