Biogas polishing is the final cleaning stage whose task is to remove trace amounts of contaminants remaining after the earlier stages, that is, after desulphurisation, cooling and drying. The name comes from the English "polish", meaning to smooth or finish. Gas after polishing is clean enough for an engine, turbine or upgrading installation that has low tolerance limits for certain compounds.

What polishing removes

Typical target components are:

  • Siloxanes, organosilicon compounds originating from cosmetics, cleaning products and some waste. During combustion they form a hard silica deposit on engine components, so engine manufacturers set limits for them.
  • Residual hydrogen sulphide (H₂S) and other sulphur compounds, which cause corrosion and degrade oil and catalysts.
  • Volatile organic compounds (VOCs), including terpenes and halogenated hydrocarbons, originating from some waste and biomass.
  • Residual moisture and aerosols, if the filter is equipped with a coalescing stage.

In upgrading installations producing biomethane, polishing also protects membrane and molecular sieve beds from compounds that could poison them. The article on biogas pre-treatment describes the broader context.

How it works

The most common solution is adsorption on activated carbon: the gas flows through a vessel filled with granules of enormous internal surface area, and the contaminant molecules settle in the pores. For special applications the carbon is impregnated, which increases its effectiveness against H₂S. Other adsorbents are also used, and in some installations the gas is additionally cooled to a low temperature to condense out some of the siloxanes and water.

The condition for effective operation is clean, dry gas. Activated carbon loses capacity when its pores fill with water or condensate. That is why a condensate separator, drying (cooling with reheating) and often preliminary desulphurisation are used upstream of the filter. Desulphurisation solutions are described in the articles on biological desulphurisation and chemical desulphurisation and activated carbon.

When it makes sense

Polishing is justified when:

  • the substrates contain siloxanes or other difficult components (municipal waste, sewage sludge, landfill gas),
  • the engine manufacturer requires lower contaminant levels than pre-treatment delivers,
  • the gas goes to upgrading or to the grid, where quality requirements are stricter,
  • earlier experience has shown accelerated wear of spark plugs or deposits in the engine.

In a typical agricultural biogas plant running on agricultural substrates, siloxanes are usually only trace amounts, and the main problem is H₂S, so a further stage is not needed everywhere.

How polishing differs from desulphurisation

Desulphurisation removes the main mass of H₂S, usually in the digester or in a separate stage, and works at high concentrations. Polishing works at low concentrations and is meant to guarantee quality "at the outlet". It is not designed to take large sulphur loads, because the bed would be exhausted in a short time. A good system therefore consists of several stages: preliminary desulphurisation, cooling and drying, and polishing at the end. The order of the stages matters more than any single device.

What to look out for

  • Breakthrough monitoring. The bed has a limited capacity. Measuring the contaminant concentration downstream of the filter is recommended, because replacement is decided by breakthrough, not by running time alone.
  • Redundancy. Two filters in a series or alternating arrangement make it possible to replace the bed without stopping the installation.
  • Safety. Spent carbon may contain adsorbed compounds and may heat up. Handling filters and replacing the bed should follow the manufacturer's instructions and the safety rules of an explosion hazard zone, and the spent bed waste must be handed over in accordance with waste regulations.
  • Pressure drop. Granules that are too fine or a damp bed increase flow resistance.

Summary

Polishing is a protective stage, not a substitute for desulphurisation. A well-designed filter, fed with dry and pre-cleaned gas, extends the life of the engine or upgrading installation, but requires monitoring and planned bed replacement. The choice of technology and parameters should be based on gas analysis and the requirements of the supplier of the biogas consumers. It helps to determine regularly the gas composition upstream and downstream of the filter, because only such data show whether the bed is really protecting the engine, and to keep a register of replacements, which over time makes it possible to predict bed life for a given installation and substrates.