Tanks and membranesExplainer

Gas membranes for biogas: PVC/PES fabrics, PE films and EPDM — properties and limitations

A gas membrane is a laminate of a carrier fabric and a coating. We explain the structure, resistance to UV, moisture and frost, and how to read a technical data sheet before purchase.

Published 4 min readFeedstockData Editorial Team

Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

Stado czarnego bydła na rozległym pastwisku na tle jesiennego lasu – hodowla przeżuwaczy to istotne źródło emisji metanu.
Photo L T Hunter / Wikimedia Commons, licence CC BY 2.0, source file; changes: cropping

A gas membrane is at once a barrier, a store and a structural element. It is usually a laminate: the carrier fabric takes the loads, and the coating or film provides tightness and protection from environmental factors. Below we discuss the types of materials and the parameters worth knowing how to read before an offer is accepted.

Structure of the laminate

A typical membrane consists of:

  1. a carrier fabric, most often polyester (PES) of high strength,
  2. a coating of PVC, PE or another polymer applied on both sides,
  3. a protective top layer (lacquer) limiting dirt deposition and UV ageing.

The fabric takes the tensile forces, so the strength of the whole depends on its density and weave. The coating provides tightness, and the lacquer prolongs the life of the surface.

Types of materials

Material Character Advantages Limitations
PES fabric with PVC coating most commonly used for roofs and cushions high strength, good weldability, known technology plasticiser ageing, sensitivity to low temperatures
Polyethylene (PE) film lighter, often single-layer, used in smaller covers and lagoons low cost, chemical resistance lower tensile strength, requires care when welding
EPDM elastomer, used in some covers and seals flexibility at low temperatures, UV resistance more difficult joining (gluing or vulcanisation), higher gas permeability

In reality more variants are available, including multilayer coatings and additives improving fire resistance. The selection criterion depends on the application: the outer membrane of a roof has different tasks than the inner membrane, which is in contact with the gas.

Weight and thickness

The weight per unit area of the laminate for biogas roofs lies in a wide range, roughly from about 900 to over 1500 g/m², and the thickness from a fraction of a millimetre to about 1.5 mm. A higher weight usually means greater strength and greater mass, which affects the fixing structure. For PE films, thicknesses are given in millimetres and can reach several millimetres in lagoon covers. There is no single "good" figure; it depends on the span, the load and the manufacturer.

Strength

The data sheet most often gives:

  • tensile strength in the warp and weft directions (in N/5 cm), usually from several to over ten thousand N/5 cm for PES fabrics with PVC,
  • tear strength (in N), important with sudden damage,
  • weld or joint strength as a percentage of the material strength.

The weld is usually the weakest point. It is worth checking whether the joint strength is given for the operating temperature.

Environmental resistance

The factors to pay attention to are:

  • UV: top coatings with lacquer and pigment limit degradation; hours of artificial ageing are declared,
  • sulphur compounds: biogas contains small amounts of sulphur compounds, which over time can affect the coating; compatibility of the material with biogas is required,
  • moisture and condensate: they affect the inside of the roof and promote moistening of the internal materials,
  • low temperatures: PVC stiffens in winter, so the data sheet is checked for the limiting flexibility temperature,
  • fire and sparking: important in explosion hazard zones, where electrostatic charges can be dangerous; this requires assessment in line with the ATEX documentation of the plant.

Gas permeability

No membrane is hermetic. Methane diffuses through the polymer in small amounts, depending on the material, thickness, pressure difference and temperature. For the plant this matters for two reasons: it affects energy losses and methane emissions to the atmosphere. The Methane Regulation (EU) 2024/1787 applies primarily to the oil, gas and coal sector, and its impact on agricultural biogas plants is limited, but it shows the direction: growing importance is attached to the measurement and reduction of methane emissions. The manufacturer should state the permeability coefficient; assessing the effect on the methane balance requires comparison with other sources of loss, such as leaks from fittings.

Welding and joining

PVC is welded by high frequency or hot air, PE by extrusion or wedge welding. The quality of the weld depends on conditions: cleanliness, temperature, pressure, time. For field repairs, welded or glued patches are used, and the strength obtained is usually lower than the factory one.

Service life and how to read the data sheet

The declared service life is usually over ten years for roof membranes, but operating conditions shorten it. In the data sheet look for: weight per unit area, tensile strength in both directions, tear strength, resistance to UV and low temperature, coating type, joining method, fire class, resistance to biogas, and the scope of the warranty and the conditions for maintaining it (for example inspections). Require that the values be given according to a specified test method.

Summary

The selection of a membrane is a compromise between strength, cost, ease of joining and resistance to operating conditions. The data sheet is a tool for verifying declarations. Permeability and its consequences for the methane balance should also be kept in mind.

Sources

  1. FNR — Themenportal Biogas (Fachagentur Nachwachsende Rohstoffe)
  2. IEA Bioenergy Task 37 — Energy from Biogas
  3. Rozporządzenie (UE) 2024/1787 — redukcja emisji metanu w sektorze energii