Safety and ATEXGuide
Machinery safety at a biogas plant: guards, emergency stops and energy lockout (LOTO)
Agitators, feeders and shredders are the most dangerous machines at a biogas plant. We discuss guards, emergency stops, LOTO and the requirements of machinery law.
Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

A biogas plant has no shortage of machines that can kill in a fraction of a second: slow-speed agitators submerged in tanks, screw and roller feeders, shredders, pumps with cutting knives, belt conveyors. What they have in common is that the movement is slow and the force enormous, so a person has no chance of pulling free once caught. This guide arranges protective measures from machine design to the service procedure.
Typical mechanical hazards
- Entanglement and drawing-in by screws, rollers, chains and conveyor shafts, as well as by clothing and hair.
- Crushing between moving and stationary parts, for example between an agitator and a wall, or between a loader arm and a structure.
- Cutting and severing by the knives of shredders and pumps with a macerator.
- Impact from ejected pieces of silage, stones or parts.
- Unexpected start-up when clearing a blockage or during repair.
The most dangerous are work at open feeder hatches, clearing blockages by hand or with a tool while the machine may start, and entering tanks with installed agitators.
Legal basis
New machines placed on the EU market must meet the requirements of Directive 2006/42/EC: risk assessment, guards, control systems, instructions and a declaration of conformity. From 20 January 2027 Regulation (EU) 2023/1230 will apply, which will replace the directive and adds, among other things, requirements for machines with software and for the cybersecurity of control systems. The obligations of the user, that is, the employer, result from occupational health and safety regulations: keeping machines in a condition that meets the requirements, training and workplace instructions. A machine bought "without a declaration" or modified by the user may require a conformity assessment.
Guards: fixed and movable
A fixed guard covers a zone to which access is not needed during operation. It is fastened with a tool so that it cannot be removed accidentally. An interlocked movable guard is needed where the operator must open the zone, for example for cleaning; the interlock stops the movement when it is opened and prevents start-up until the guard is closed. The general requirements for guards are described by the standard EN ISO 14120, and the principles of interlocks and prevention of unexpected start-up by EN ISO 14119 and EN ISO 14118.
Practical notes:
- Safety distances from moving parts must make it impossible to reach the hazardous zone by hand through openings.
- A guard must not be removed or bypassed for convenience; any change requires a risk assessment.
- The power inlet of a feeder with a hopper should have a grating or a structure limiting access to the screw.
Emergency stops
An emergency stop (EN ISO 13850) is a complementary measure and does not replace guards. It should be red on a yellow background, easy to operate in a single movement, accessible in places where a person may be caught, and cause the machine to stop with a restart lockout until manually reset. In systems with many machines, it is worth stating clearly which devices a given emergency stop shuts down. The performance of emergency stops is checked regularly, as part of inspections.
Lockout and tagout of energy sources (LOTO)
The LOTO (lockout/tagout) procedure consists of disconnecting energy sources, locking them in the off position with one's own lock and marking them with a tag. Steps:
- Notifying the operators and stopping the machine in the normal way.
- Disconnecting all energy sources: electrical, hydraulic, pneumatic, gravitational.
- Locking the isolators with the padlock of each servicing worker, together with a tag bearing a name and date.
- Releasing residual energy: depressurising, supporting raised parts, run-down of rotating masses.
- Verifying effectiveness: a start-up attempt, which should result in no movement.
- After the work is finished, checking that nobody is in the zone, removal of the padlocks by their owners and a controlled start-up.
Residual energy and work at open hatches
Agitators and screws still run down after switch-off; hydraulics and springs store energy. A tank after emptying is also a space hazardous because of gases, so entering it is subject to separate regulations and a procedure. Work at a feeder hatch requires disconnecting the power and protection against substrate falling from above.
Documentation, inspections and training
Machinery safety does not end with good guards on the day of acceptance. For each machine it is worth keeping a card: the manufacturer's instructions, the declaration of conformity, the result of the risk assessment, the date of the last inspection of guards and emergency stops, and a record of any modifications. Operators should know the workplace instructions and be able to indicate where the nearest emergency stop is. After every mechanical failure, even without an accident, it is worth checking whether the guards have been damaged or removed, and whether they were put back after the repair. Work contracted to external firms needs separate attention: their workers must learn the LOTO rules in force at the plant before they approach the machines. For agitator failures, the guidance in the article Agitator failures in a digester is useful.
Typical mistakes
- Bypassing the guard door interlock with a bracket or tape.
- Clearing a blockage while the machine is running.
- One padlock for many people or no individual locks.
- No test after lockout.
- Machine modifications without a new risk assessment.