NIR spectroscopy of substrates: rapid assessment of dry matter and methane potential without waiting for the laboratory

NIR spectroscopy gives a result in several dozen seconds, but it is only as good as its calibration. We explain the principle, the range of applications and cooperation with the laboratory.

Published 4 min readFeedstockData Editorial Team

Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

Dłonie w niebieskich rękawiczkach trzymają probówkę z próbką, rozmyte tło laboratorium.
Photo USDAgov / Wikimedia Commons, public domain, source file; changes: cropping

At an agricultural biogas plant, the largest part of the costs is substrate, and its quality changes from delivery to delivery. Laboratory analysis of dry matter or organic dry matter takes time, and BMP takes weeks to wait for. Near-infrared (NIR) spectroscopy gives an estimate in several dozen seconds, but it is an estimate, not a direct measurement. Below we explain when it is useful.

How NIR works

Near-infrared radiation, in the range of about 780–2500 nm, illuminates the sample. Molecules absorb it at wavelengths associated with the overtones and combination vibrations of hydrogen-containing bonds: C–H (fats, carbohydrates), O–H (water, sugars, cellulose) and N–H (proteins). The spectrum is therefore rich, but broad and overlapping bands mean that composition cannot be read from it directly, as in a simple chemical test.

Chemometric calibration

That is why a model is needed. The standard procedure:

  1. A large number of samples representative of a given type of substrate is collected (e.g. maize silage from many fields and years).
  2. Each sample is scanned by NIR and analysed with reference methods: dry matter, organic dry matter, protein, fibre and, in more advanced calibrations, also the BMP test result.
  3. The relationship between the spectrum and the result is modelled statistically, most often by partial least squares (PLS).
  4. The model is checked on samples not used in the calibration and the error is reported, e.g. RMSEP (root mean square error of prediction).

The key point: NIR does not know "methane"; it knows the correlation of the spectrum with a laboratory result that someone established earlier. For dry matter, protein or fibre the correlations can be strong; for BMP they are weaker, because methane potential depends on the availability of the fractions, not only on composition.

Errors and limits of use

  • Sample coverage. The model is reliable only within the spectra on which it was built. A new variety, a different harvest date or a preservative additive may shift the spectrum outside the range.
  • Sample preparation. Surface moisture, particle size and temperature affect the result; a measurement through a layer of silage in the clamp is not the same as a measurement of a ground sample.
  • Relative error. RMSEP for silage dry matter is sometimes on the order of a fraction of a percentage point to one point; for organic dry matter and BMP it is larger. The exact values depend on the calibration — demand them from the supplier.
  • Instrument drift. Temperature changes and ageing of the light source require periodic standardisation.

Types of devices

Laboratory instruments have stable conditions and very good repeatability, but require sampling. Handheld spectrometers allow measurement in the clamp or at unloading; they are convenient, and their error is larger. Inline sensors mounted on a conveyor or in a hopper measure the stream continuously and can control dosing, but require calibration for the specific installation site.

Applications at a biogas plant

  • Silage control: a quick check of dry matter at successive exposures of the clamp allows weight-based doses to be corrected, because the same fresh mass means a different amount of organic dry matter.
  • Control of deliveries of waste substrates and assessment of batch homogeneity.
  • Balancing the mix: with a mix of many components, current dry matter and organic dry matter make it easier to calculate the loading and keep production forecasts consistent.
  • Support for purchase planning based on parameters, not only on price per tonne.

For large biogas plants, NIR is sometimes part of a broader instrumentation system, described in the article on monitoring and automation.

Model of cooperation with the laboratory

The most sensible approach is two-layer control:

  • NIR for routine decisions (a few to a dozen or so measurements a day or a week, depending on variability),
  • periodic samples sent to the laboratory (e.g. every dozen or so deliveries or when the raw material source changes): dry matter, organic dry matter and, once per season, BMP,
  • comparison of NIR results with laboratory ones and updating of the calibration when the discrepancy grows.

In this way NIR does not replace the laboratory, but reduces the number of analyses needed to maintain control and shortens the reaction time. This approach remains neutral with regard to the choice of laboratory and instrument supplier; what matters is that reference results come from standardised methods and are comparable over time.

What to ask the supplier

  • What samples was the calibration built on (number, type, years, region) and what is the RMSEP for my parameters?
  • How and how often is the model updated, who does it and for what fee?
  • Does the result show a measure of uncertainty or a warning when the spectrum falls outside the range?
  • Can I carry out a parallel test with my own samples and my own laboratory before purchase?

We describe the assessment of an offer in the order of TRL, references and guarantees in the guide How to assess a new technology at a biogas plant.

Sources

  1. KTBL — Kuratorium für Technik und Bauwesen in der Landwirtschaft, strona główna (publikacje i dane o biogazie)
  2. VDLUFA — Verband Deutscher Landwirtschaftlicher Untersuchungs- und Forschungsanstalten, Methodenbuch (metody analiz pasz)
  3. FNR — Leitfaden Biogas: Von der Gewinnung zur Nutzung