Cogeneration and enginesExplainer
PES and high-efficiency cogeneration: how to calculate primary energy savings
What primary energy savings (PES) are, how to calculate them under the Energy Efficiency Directive and what the high-efficiency cogeneration threshold looks like.
Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

The concept of high-efficiency cogeneration derives from European Union law and sets out when combined production of electricity and heat is really more efficient than separate generation. The measure is primary energy savings (PES), and the threshold of high-efficiency cogeneration is above 0 for small and micro units and at least 10% for the others. The text is based on Directive (EU) 2023/1791, which recast and replaced Directive 2012/27/EU, and on the formula known from its predecessor, and it explains the formula and a worked example. The figures are illustrative. The legal position is as at the date of publication; in practical application the current wording of the provisions and national rules for determining the indicators must be checked.
The idea of PES
Cogeneration makes it possible to use heat that in a conventional power plant ends up in the cooling tower. PES answers the question: how much fuel will we save if the same amount of electricity and heat is produced in one unit instead of in a power plant and a boiler? The result is expressed as a percentage.
The formula
The method of calculating primary energy savings derives from Directive 2012/27/EU and is retained in Directive (EU) 2023/1791 (in the annexes on cogeneration). The formula has the form:
PES = 1 − 1 / (CHP Hη / Ref Hη + CHP Eη / Ref Eη)
where:
- CHP Hη is the thermal efficiency of cogeneration (useful heat / fuel),
- CHP Eη is the electrical efficiency of cogeneration (electricity from cogeneration / fuel),
- Ref Hη is the reference efficiency for separate heat production,
- Ref Eη is the reference efficiency for separate electricity production.
The reference efficiencies are set by the European Commission in a delegated act (Commission Delegated Regulation (EU) 2015/2402 with amendments). They depend on the fuel (biogas has a separate value), the year of construction of the unit and, in the case of electricity, also on corrections for ambient temperature and grid losses, depending on the place of connection. The exact values should be taken from the current acts, not from the examples in articles. The formula applies to useful heat, that is heat that is actually used for economically justified needs.
Thresholds
- Micro-cogeneration (below 50 kW of electrical power) and small-scale cogeneration (below 1 MW): high-efficiency if PES is greater than zero.
- Other units (from 1 MW upwards): PES of at least 10%.
For agricultural biogas plants with a capacity usually below 1 MW, a positive PES is therefore sufficient, which at typical efficiencies and a realistically used heat is usually easy to meet.
An illustrative example
Working assumptions, not data from a specific installation: a unit with an electrical efficiency of 40% and a thermal efficiency of 42%, of which only 60% of the heat is actually used (the rest is dumped by cooling). Let us take the reference efficiencies for the example as: Ref Eη = 0.45, Ref Hη = 0.90 (nominal values, serving only to demonstrate the method).
- CHP Eη = 0.40.
- CHP Hη (useful) = 0.42 × 0.60 = 0.252.
- PES = 1 − 1 / (0.252/0.90 + 0.40/0.45) = 1 − 1 / (0.280 + 0.889) = 1 − 1 / 1.169 = 1 − 0.855 = 0.145, that is about 14.5%.
With full use of heat (0.42): 1 − 1 / (0.467 + 0.889) = 1 − 0.737 ≈ 26%. With no use of heat (CHP Hη = 0): 1 − 1 / 0.889 = −12.5%, that is a negative PES and no high-efficiency cogeneration status. The example shows the main message: the result is determined above all by the share of heat used, not by the efficiency of the engine alone.
What this means for a biogas plant
- Useful heat has to be documented. Heat meters and offtake data are necessary, not only a measurement of the unit's thermal power.
- The digesters' own heat needs can usually be counted as useful heat to the extent provided for by national rules, but the detailed rules have to be checked in the current regulations.
- The boundary of cogeneration. When total efficiency is low or when part of the energy comes from a boiler, production has to be separated in line with the method in the directive.
- Documenting PES is sometimes needed to obtain support, confirmations or exemptions provided for in national law, but the conditions and scope are set by national legal acts, with which the owner should become familiar as at the date of the decision.
Summary
PES is a simple indicator based on the efficiencies of the unit and the reference efficiencies. At a biogas plant with a capacity below 1 MW a PES above zero is sufficient, but good practice is to aim for the greatest possible use of heat. For any formal calculation the current reference efficiencies from the relevant acts must be used. The way of using heat, on which the result depends, is described in the article Waste heat from cogeneration at a biogas plant: balance, seasonality and ways of use.
Sources
- Dyrektywa (UE) 2023/1791 w sprawie efektywności energetycznej (przekształcenie dyrektywy 2012/27/UE)
- Dyrektywa 2012/27/UE w sprawie efektywności energetycznej (zastąpiona dyrektywą 2023/1791)
- Rozporządzenie delegowane Komisji (UE) 2015/2402 — zharmonizowane sprawności referencyjne
- Internetowy System Aktów Prawnych (ISAP) — przepisy krajowe