A biogas plant in hot weather: digester temperature, cooling, foaming and risks to people

In summer a biogas plant has surplus heat, faster-spoiling substrates and overheating equipment. We describe the risks to the process and to people, and the measures.

Published 4 min readFeedstockData Editorial Team

Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

Wiosenny krajobraz polskiej wsi: falujące pola rzepaku i pszenicy, wioska z wieżą kościoła i rzędy topoli.
Illustration: FeedstockData (AI, Google Gemini)

Summer is a period of particular risk for a biogas plant: there is too much heat, substrates spoil faster, and equipment and people work close to the limits of tolerance. Below we explain what happens to the process and infrastructure at high ambient temperatures and which organisational measures limit the effects. The differences between mesophilic and thermophilic operation are covered in a separate text, and the use of CHP heat in the material on waste heat.

Digester temperature and the condition of the bacteria

Mesophilic fermentation usually takes place in the range of approx. 37–42 °C. Methanogens are sensitive to change: a sudden rise of a few degrees can reduce methane production, and exceeding the limit of approx. 42–44 °C often causes gradual inhibition. The digester itself is well insulated and has a large thermal capacity, so it usually does not heat up dramatically from the sun. The real problem is the heat supplied by its own heating system and the heat generated in the process itself when exchange with the surroundings is weaker.

It is worth observing not only the absolute value but also the rate of change. A rise of a few degrees within a few hours is more dangerous than a slow settling at a slightly higher level.

Surplus CHP heat and no offtake

In summer the demand for heat decreases: buildings are not heated, and dryers operate seasonally. The CHP engine still produces heat in proportion to its power. If there is no consumer, the system must dissipate it in an emergency cooler. At a high air temperature its capacity falls, and the engine may run at limited power or shut down because the coolant temperature has been exceeded. Practical measures:

  • checking the cleanliness of cooler fins and the operation of fans before the season,
  • checking the three-way valves and circulation pumps,
  • deciding which heat offtake has priority (digester, dryer, heating),
  • checking whether the digester heating circuit has a cut-off function when the temperature is exceeded.

Substrates: faster spoilage and effects on the process

At high temperature, yeasts and moulds develop faster in silage when the clamp face is being removed, and fresh substrates (food waste, slurry, grass silage) are more quickly subject to uncontrolled fermentation. The composition then changes: the share of acids rises, the share of readily available energy falls, and part of the material is lost even before the digester. As a result, a dose calculated according to the old assumptions gives a different result in the digester. Monitoring volatile fatty acids and observing foam after a change in feedstock quality make it possible to detect a disturbance quickly. Storage rules are discussed in the text on silage. Reducing the area of the exposed face and removing it quickly are the simplest measures.

Odours and the surroundings

Summer temperatures intensify odour emissions from storage, unloading and digestate areas. They are limited by quickly covering exposed substrates, avoiding transfers in the hottest hours, and adjusting the timing of digestate spreading to the wind direction and time of day. Good relations with neighbours are part of operation, not only a matter of image.

Control cabinets, frequency converters, electronics

Frequency converters and control cabinets have a defined maximum ambient temperature. Blocked filters and dusty heat sinks worsen cooling, so in hot weather shutdowns with an overheating alarm occur more often. Measures: cleaning fan filters, ensuring airflow, shielding from direct sun, checking the room temperature. A simple thermometer with logging in the cabinet provides data for assessment.

People: working in the heat

Walking the tanks and working on the roof require appropriate organisation: breaks, access to water, avoiding work on roofs and at tanks in the greatest heat, rules for working in pairs. An important warning: high temperature intensifies the release of gases from substrates and digestate, so the safety rules at tanks and hazard zones remain fully in force, and heat is an additional factor, not a substitute.

Foaming and changes in the process in summer

Faster spoilage of substrates and changes in temperature can promote foaming. When foam appears in the digester, it also matters for measurements: it disturbs level readings and can get into gas lines. The operator should therefore check the gas composition, volatile fatty acids and level indications more often than usual during hot weeks, and introduce any major change of feedstock gradually. An extensive discussion of the causes of foam is in a separate text; what matters here is that in summer many risk factors overlap at once, so it is better not to combine a substrate change, a shutdown for repairs and work on the cooling system in a single week.

The balance and seasonality of engine heat are described in the text on waste heat from CHP, and the causes of foam in the text on foaming in the digester.

What to remember

  • Before the season, prepare emergency cooling and check its capacity.
  • Observe the rate of change of digester temperature, not only the value.
  • Shorten the exposure time of substrates and reduce the exposed surface.
  • Plan people's work with the heat in mind.

Sources

  1. FNR - Fachagentur Nachwachsende Rohstoffe (Niemcy)
  2. Weiland P. (2010), Biogas production: current state and perspectives, Appl. Microbiol. Biotechnol. 85, 849–860