Operation and failuresGuide

Blockages and failures in the transport of slurry and liquid substrates: pipelines, gate valves and pumps

Slurry transport usually fails gradually: a pump loses capacity and a gate valve stops closing fully. We show the symptoms, diagnostics and prevention.

Published 4 min readFeedstockData Editorial Team

Other language versions: Polski, Deutsch, Español, Français, Italiano, Nederlands.

Samojezdna maszyna do aplikacji gnojowicy z szeroko rozłożonymi ramionami węży na łące.
Photo An-d / Wikimedia Commons, licence CC BY-SA 3.0, source file; changes: cropping

The transport of liquid substrates seems a simple part of the plant until it stops: slurry with fibres, sand and gas in suspension is a difficult medium for pumps and fittings. Failures are rarely sudden; they are usually preceded by a period of decreasing performance. The selection of pumps is described in the article on pumps at a biogas plant, and solid substrate feeders are a different topic. Here we focus on blockages and failures in operation.

Main failure mechanisms

Clogging. Fibres (straw, feed residues, twine, film) wind around the impeller, lodge in elbows and gate valves and form braids that over time reduce the cross-section. Sand and mineral particles settle in horizontal sections when the fluid velocity is too low and form sludge. After a longer shutdown the pipeline may be partly blocked by sediment.

Airlock and cavitation. Air drawn in through leaking joints on the suction side, or a low level in the tank, causes airlock. The effects: noise, a drop in performance, vibration. Cavitation (the formation and collapse of vapour bubbles) occurs when the inlet pressure is too low, and damages the impeller and casing.

Abrasive wear. Sand acts like sandpaper: impellers, bodies, mechanical seals and gland packings wear away. The result is decreasing performance and leakage, and in positive displacement pumps liquid slipping back through the clearances.

Blocked gate valves. Sediment lying in the gate valve seats, lack of movement for a long time and corrosion of the stems cause a gate valve not to close fully or not to open fully.

Symptoms without an alarm

Many of these faults do not trigger an alarm, because the parameters are still within the set thresholds. Indications:

  • a longer time to transfer the same mass,
  • a rising motor current with falling flow (blockage) or a falling current (airlock, wear),
  • unstable discharge pressure,
  • leaks around seals and flanges,
  • noise and vibration, especially in centrifugal pumps,
  • uneven filling of tanks at the same settings.

Diagnostics in three steps

Comparing three signals makes it possible to distinguish causes at a preliminary level:

Discharge pressure Motor current Flow Probable cause
rises rises falls blockage in the pipeline or gate valve
falls falls falls airlock or impeller wear
unstable unstable unstable cavitation, low suction level
unchanged unchanged falls measurement error or leak upstream of the meter

Such a table is a guide, not proof; the final diagnosis is made by inspecting the pump and pipeline. It is worth recording "healthy" values after commissioning or servicing, because only a reference to them makes it possible to detect a deviation.

Procedure during a blockage

  1. Stop the pump before the impeller is damaged or the motor overheats.
  2. Isolate the section with gate valves, allowing for residual pressure and liquid leakage.
  3. Locate the blockage: by comparing pressures, opening an inspection port or removing a nozzle.
  4. Clear the blockage mechanically or flush it with water (always in line with the manual and safety procedures, because the liquid may contain dissolved H₂S and be under pressure).
  5. Record the location and cause to avoid repetition.

Dismantling a pump or opening pipelines with liquid from the digester requires compliance with health and safety rules, including ventilation and a gas detector.

Prevention

  • shredding and screening of fibrous substrates upstream of the pump (see shredding of substrates and removal of foreign bodies),
  • limiting sand at the inlet (settling tanks, sumps),
  • flushing pipelines after breaks in operation and after a change of substrate,
  • periodic checking of the wear of impellers and seals, planned replacement according to operating hours,
  • regular movement of gate valves that are operated rarely,
  • monitoring of current and pressure with alarms for deviation from the baseline,
  • a stock of critical parts (seals, impellers, the shredder knife).

It also helps to label pipelines and gate valves and to keep a simple hydraulic diagram updated after every change. In an emergency, when a blockage has to be located quickly, an operator who knows which gate valves isolate a given section saves hours. It is also good to establish which section is most often clogged and add an inspection or flushing point there. Such small improvements, made once, shorten every subsequent failure. After a longer break, especially after frosts, before starting the pump it is worth checking by hand that the impeller turns and that the pipeline is not frozen or blocked with sediment, because starting under load damages seals and shafts. It also helps to write down the pressure and current values of the pumps after every service as a comparison reference.

Key takeaways

Failures in the transport of liquid substrates have predictable causes: fibres, sand, air and sediment. Comparing pressure, current and flow makes it possible to distinguish them at a preliminary level. The most effective prevention is limiting contaminants at source, regular flushing and trend monitoring.